Mound Systems for On-site Wastewater Treatment
Siting, Design and Construction in Ohio
Bulletin 813
Mound System Design Example
Step 5. Determine the Distribution Area Width.
Distribution Area Width = (Linear Loading Rate)/(Sand Fill Loading Rate)
Distribution Area Width:
Distribution Area Width
= (Linear Loading Rate)/(Sand Fill Loading Rate)
= (4 gpd/lf)/(1 gpd/ft2)
= 4 ft
Back
|
Forward
|