Mound System Design Example

Step 5. Determine the Distribution Area Width.

Distribution Area Width = (Linear Loading Rate)/(Sand Fill Loading Rate)

Distribution Area

Distribution Area Width:
Distribution Area Width = (Linear Loading Rate)/(Sand Fill Loading Rate)
= (4 gpd/lf)/(1 gpd/ft2)
= 4 ft